Sciact
  • EN
  • RU

Virtual stent deployment in cerebral vessels with an aneurysm Научная публикация

Журнал AIP Conference Proceedings
ISSN: 0094-243X
Вых. Данные Год: 2018, Номер статьи : 040044, Страниц : DOI: 10.1063/1.5065318
Авторы Kuianova Iuliia O. 1,2 , Parshin Daniil V. 1,2
Организации
1 Lavrentyev Institute of Hydrodynamics
2 Novosibirsk State University

Реферат: In this paper, a qualitative as well quantitative assessment of the effect of the flowdiverter stent on the hemodynamics of the human brain circulation is carried out. Numerical simulation of a virtual stent deployment in cerebral vessels with an aneurysm for one clinical case of an actual patient has been performed. In the course of the numerical experiment, various models of blood rheology are used, which is in a good agreement with the experimental data. The calculations are carried out in the commercial software ANSYS 17.2. It is shown that after the stent installation the flow through the aneurysm neck reduces. The cerebral blood flow condition becomes closer toward the state of a healthy person. Changes in the magnitude of wall shear stress in the stent region are indicative of the possible recanalization of the aneurysm.
Библиографическая ссылка: Kuianova I.O. , Parshin D.V.
Virtual stent deployment in cerebral vessels with an aneurysm
AIP Conference Proceedings. 2018. 040044 . DOI: 10.1063/1.5065318 Scopus РИНЦ OpenAlex
Идентификаторы БД:
Scopus: 2-s2.0-85056360178
РИНЦ: 37262979
OpenAlex: W2899271231
Цитирование в БД: Пока нет цитирований